Each question shows where it is from (session, paper and question number, or the book), the section it tests, and whether it is Core (Paper 1/3) or Extended (Paper 2/4). Choose an answer for each question, tap Check my answers to mark that part, then Show solutions to see the working. Your best score is saved on this device.
APart A 10 questions
Questions 1–10.
A magnet moves into the same coil of wire in three arrangements. X: strong magnet, moving slowly. Y: weak magnet, moving slowly. Z: strong magnet, moving quickly. Which arrangement induces the largest e.m.f., and which the smallest?
Which voltage–time graph shows the output of a simple a.c. generator? A: humps above zero only (touching zero); B: a sine wave above and below zero; C: separate humps with gaps along zero; D: a constant voltage.
A simple a.c. generator gives a sine-shaped voltage that goes positive and negative as the coil turns. A and C never reverse; D is d.c.
What is an advantage of transmitting electricity at a high voltage?
For the same power, a higher voltage means a smaller current (P = IV). A smaller current heats the cables less, so less energy is wasted. Electricity does not travel faster, and high voltages are more dangerous, not safer.
A transformer has 200 turns on its primary coil, which is connected to a 240 V a.c. supply. Its output is 60 V a.c. How many turns are on the secondary coil?
- StepNs = 200 × 60 ÷ 240
- StepNs = 50 turns (a step-down transformer)
What does a step-up transformer increase?
It increases the voltage; the current goes DOWN. It cannot increase energy or power (at best 100% efficient).
A student makes four transformers and labels each as step-up or step-down. Which row is labelled correctly?
A step-down transformer has fewer turns on the secondary than on the primary: 20 → 10 is step-down. 5 → 5 changes nothing, 10 → 5 is step-down (not step-up) and 10 → 20 is step-up (not step-down).
Four arrangements of two coils on an iron core. A: a.c. input to a coil of few turns, output from a coil of many turns. B: d.c. input, few turns to many turns. C: a.c. input, many turns to few turns. D: d.c. input, many turns to few turns. Which can step up a voltage?
A transformer needs a.c. (d.c. gives no changing field). To step up, the output (secondary) coil needs more turns than the input coil: A.
Which metal is used for the core of a transformer?
Soft iron is magnetised and demagnetised easily, so it follows the changing (alternating) field with little energy loss. Steel stays magnetised; aluminium and copper are not magnetic.
Which statement about transformers is true?
A step-up transformer has more secondary turns, so it increases the voltage. A step-down transformer increases the current, has fewer secondary turns, and is what a low-voltage lab supply uses.
An a.c. generator’s coil starts at right angles to the magnetic field and is turned slowly. The e.m.f.–time graph is a sine curve starting at zero at O, rising to a peak P, back to zero at Q, down to a trough R and back to zero at S. Which section represents three-quarters of a turn?
One complete cycle (O to S) = one turn. Each quarter of the cycle is a quarter of a turn, so ¾ turn ends at the trough, R.
BPart B 9 questions
Questions 11–19.
A wire is moved through the gap between the poles of a magnet, and a voltmeter measures the e.m.f. across its ends. Which gives the highest reading?
The induced e.m.f. increases with the speed of the wire and the strength of the field (the wire cuts field lines faster).
A wire moved across a magnetic field has a current induced in it. This current interacts with the field to give a force on the wire. In which direction is this force?
An induced current always opposes the change that causes it (Lenz’s law). Here the change is the motion of the wire, so the force on it acts against its movement: you must do work to keep it moving, which is where the electrical energy comes from.
A bar magnet falls vertically through a solenoid connected to a meter. Diagram 1: the magnet, S end first, is approaching the top end X of the solenoid. Diagram 3: the magnet has passed through and is moving away below the solenoid, with its N end (the upper end) nearest it; X is still the top end. Which poles are induced at X?
The induced current opposes the change. Diagram 1: the S pole approaches X, so an S pole is induced at X to repel it. Diagram 3: the N pole is leaving the bottom, so an S pole forms at the bottom to attract it back; the top, X, is then an N pole.
A straight metal rod PQ lies in the horizontal magnetic field between a N pole (on the left) and a S pole (on the right). The rod is horizontal and points away from you, with P nearest you and Q furthest away; it is connected to a resistor to complete a circuit. The induced current must flow along the rod from P to Q. Directions: A – vertically upwards; B – vertically downwards; C – towards the N pole; D – towards the S pole. In which direction should the rod be moved?
Use Fleming’s right-hand rule: first finger along the field (N → S), second finger along the current (P → Q). The thumb gives the motion: upwards. Moving along the field lines (C or D) would induce nothing; moving down would reverse the current.
Why is electrical energy sent along transmission lines at a high voltage?
For the same power, a higher voltage means a smaller current, so much less energy is wasted heating the cables.
Which device changes a 240 V a.c. supply into 20 V a.c.?
A (step-down) transformer changes the size of an alternating voltage. A generator produces e.m.f.; a relay is a switch; a voltmeter only measures.
A simple a.c. generator has a coil turning between N and S poles, with its ends at G and H. What is connected to G and H so it can supply alternating current to an external circuit?
Slip rings keep each end of the coil connected to the same brush, so the output is alternating. A split-ring commutator would give d.c.
A transformer is 100% efficient. Which pair of equations are both true for it?
100% efficient: power in = power out, IpVp = IsVs. The voltage ratio equals the turns ratio, Vp/Vs = Np/Ns, which is the same as Vp/Np = Vs/Ns.
A step-down transformer is 100% efficient. Its input is 240 V a.c. and its output is 60 V a.c. The current in the primary coil is 0.50 A. What is the current in the secondary coil?
- StepIs = 240 × 0.50 ÷ 60 = 2.0 A