How this practice test works
The questions cover every section of chapter 21:
- 21.1 Generating electricity
- 21.2 Power lines and transformers
- 21.3 How transformers work
Each question shows where it is from (session, paper and question number, or the book), the section it tests, and whether it is Core (Paper 1/3) or Extended (Paper 2/4). Choose an answer for each question, tap Check my answers to mark that part, then Show solutions to see the working. Your best score is saved on this device.
APart A 10 questions
Questions 1โ10.
A wire moves downwards, at right angles to a magnetic field between N and S poles. Three changes are suggested: 1 โ move the wire faster; 2 โ make the magnetic field weaker; 3 โ reverse the direction of the field. Which changes increase the induced e.m.f.?
Moving the wire faster cuts the field lines faster, so a bigger e.m.f. is induced. A weaker field makes it smaller, and reversing the field only reverses the direction of the e.m.f.
A student pushes a bar magnet into a coil connected to a meter, and a small current flows. Which change would give a bigger current?
The induced e.m.f. depends on how quickly field lines are cut: a stronger magnet, faster movement or more turns increase it. Reversing the movement only reverses the current, and moving the coil instead of the magnet (at the same speed) gives the same result.
A laptop transformer changes 240 V mains to 20 V. Its secondary coil has 600 turns. What type is it, and how many turns are on the primary coil?
- Voltage goes downstep-down
- StepNp = 600 ร 240 รท 20 = 7200
A transformer has 400 turns on its primary coil, connected to 240 V mains. Secondary coil 1 has 2500 turns and secondary coil 2 has 20 turns. What are the p.d.s across the secondary coils?
- Coil 1240 ร 2500 รท 400 = 1500 V
- Coil 2240 ร 20 รท 400 = 12 V
A simple electric generator induces an e.m.f. Which change would increase the induced e.m.f.?
The induced e.m.f. increases with more turns on the coil, a stronger magnetic field and faster rotation. Moving the poles apart or weakening the field reduces it; reversing the field only reverses the e.m.f.
A transformer has Np turns on its primary coil and Ns on its secondary; the voltages across them are Vp and Vs. Which relationship is correct?
The voltages are in the same ratio as the numbers of turns: Vp รท Vs = Np รท Ns.
In the National Grid: power station (A) โ step-up transformer โ overhead transmission cables (B) โ step-down transformer โ (C) โ step-down transformer โ houses (D). Where is the voltage highest?
The step-up transformer raises the voltage for the long transmission cables (B), so the current, and the energy lost heating the cables, is small. Step-down transformers then lower it for homes.
A transformer has 550 turns on the input coil and 115 turns on the output coil. The input voltage is 22 000 V. What is the output voltage?
- StepVs = 22 000 ร 115 รท 550 = 4600 V
A straight conductor WZ runs left (W) to right (Z) through the gap between a magnetโs N pole (above) and S pole (below). Arrow P points up, arrow Q points down, arrow R points along the conductor towards Z. When the conductor is moved, electrons flow along it from Z to W.
Which way was it moved?
- Fieldfrom N to S: downwards
- Conventional currentopposite to electron flow: W โ Z
- Motionat right angles to both: into or out of the page; Fleming's right-hand rule gives OUT
- A, Bmoving up or down is along the field lines: no current is induced.
- Cmoving along the wire induces no current either.
Which component is not part of an a.c. generator?
An a.c. generator uses slip rings so the output alternates. A split-ring commutator is used in d.c. motors (and d.c. dynamos).
BPart B 9 questions
Questions 11โ19.
A conductor in a complete circuit moves across a magnetic field and a current is induced in it. Which statement about the induced current is correct?
This is Lenzโs law: the induced currentโs magnetic effect opposes the change that produced it (energy conservation).
Which component is part of a d.c. motor but not of a simple moving-coil a.c. generator?
Both a d.c. motor and a simple a.c. generator have a coil, a magnet and brushes. The d.c. motor needs a split-ring commutator to reverse the current every half turn; an a.c. generator uses slip rings instead.
A wire XY runs horizontally, front to back, through the gap between an S pole on the left and an N pole on the right, and is connected to a resistor R. The induced current must flow in the wire from Y (front) to X (back). Arrows: A โ vertically up; B โ vertically down; C โ towards the S pole; D โ towards the N pole. Which way must the wire move?
Use the right-hand (dynamo) rule: first finger along the field (N to S, to the left), second finger along the induced current (from front to back), and the thumb gives the motion: downwards. Moving along the field (C, D) cuts no field lines and induces nothing.
A simple a.c. generator has a coil turning between N and S poles, connected to an oscilloscope through slip rings and brushes. Which row is correct?
Slip rings give a.c. The e.m.f. is zero when the sides of the coil move along the field lines, which happens when the coil is vertical (its plane across the field), as drawn.
A transformer that is 100% efficient has 4500 turns on the primary coil and 900 on the secondary. The primary has a current of 1.5 A at 240 V.
What is the current in the secondary coil?
- Secondary voltageVs = 240 ร 900 รท 4500 = 48 V
- Power in = power out1.5 ร 240 = Is ร 48
- CurrentIs = 360 รท 48 = 7.5 A
- A (0.30 A)the voltage falls by 5, so the current must RISE by 5 to keep the power the same; 1.5 รท 5 is backwards.
- D (360 A)360 is the power in watts.
A transformer is 100% efficient. Its primary voltage is 3.0 V; the secondary voltage is 5.0 V and the secondary current is 2.0 A. What is the primary current?
- StepIp = 5.0 ร 2.0 รท 3.0 = 3.3 A
What types of current are in the primary and secondary coils of a step-up transformer?
A transformer needs a changing magnetic field, so the primary must carry a.c. The induced current in the secondary is also a.c. A step-up transformer only changes the voltage.
For a transformer to be as efficient as possible, what should the coils and the core be made of?
Thick wire has a lower resistance, so less energy is wasted heating the coils. A soft iron core is easily magnetised and demagnetised.
A 12 V, 36 W lamp works normally from a 100% efficient transformer connected to 240 V a.c. mains. The primary coil has 1200 turns. Which row gives the secondary turns and the current in the mains wires?
- StepNs = 1200 ร 12 รท 240 = 60
- Stepmains current = 36 รท 240 = 0.15 A
Your overall result
Check every section above to fill this in. Your best attempt is remembered on this device.