How this practice test works
The questions cover every section of chapter 21:
- 21.1 Generating electricity
- 21.2 Power lines and transformers
- 21.3 How transformers work
Each question shows where it is from (session, paper and question number, or the book), the section it tests, and whether it is Core (Paper 1/3) or Extended (Paper 2/4). Choose an answer for each question, tap Check my answers to mark that part, then Show solutions to see the working. Your best score is saved on this device.
APart A 10 questions
Questions 1โ10.
A straight wire lies at rest between two magnet poles, at right angles to the field. Which action does not induce an e.m.f. in the wire?
An e.m.f. needs relative motion between the wire and the field (the wire must cut field lines). Moving both together means no relative movement.
Which of these is not essential for electromagnetic induction?
An e.m.f. is induced whenever a conductor cuts magnetic field lines. A single straight wire moved through a field works; a coil just gives a bigger e.m.f.
Which statement is correct?
For the same power (P = IV), a higher voltage means a smaller current in the cables. Less current means much less energy wasted as heat in the cables (P = IยฒR), so the power is transmitted more efficiently.
- Ait is power (energy) that is transmitted, not "current".
- B, Dthe current is stepped DOWN, not up.
A student pushes a magnet into a coil connected to a voltmeter, which shows the size of the induced e.m.f. Which of these does not affect the size of the e.m.f.?
The e.m.f. is bigger with a stronger magnet, a faster movement and more turns. Reversing the magnet only reverses the direction of the e.m.f., not its size.
Three circuits each run from a d.c. supply. In circuit X, lamp X is connected to the secondary coil of a transformer whose primary coil is in the d.c. circuit. In circuit Y, lamp Y is connected across a thermistor that is in series with a resistor. In circuit Z, lamp Z is connected across an LDR that is in series with a resistor. In which lamps is there a current?
A transformer needs a changing current. With d.c., the field is steady, no e.m.f. is induced, and lamp X stays off. Lamps Y and Z are connected across components carrying a current, so there is a p.d. across them and they light.
A transformer in a computer changes the mains voltage of 240 V to 12 V. Its secondary coil has 2000 turns. Which statement is correct?
- Step240 V โ 12 V is a step-down transformer
- StepNp = 2000 ร 240 รท 12 = 40 000 turns
Which transformer can change a 240 V a.c. input into a 15 V a.c. output?
- Step240 รท 15 = 16, so the primary needs 16 times as many turns
- Step1200 รท 75 = 16 โ (800 รท 40 = 20; 1000 รท 25 = 40; 2400 รท 15 = 160)
A transformer has 460 turns on the primary coil and 24 on the secondary. The primary voltage is 230 V. What is the secondary voltage?
- StepVs = 230 ร 24 รท 460 = 12 V
Why is the core of a transformer made of soft iron?
Soft iron is easily magnetised and demagnetised, so it carries the changing magnetic field of the primary coil through the secondary coil. No current flows through the core itself.
A wire, connected to a resistor R, lies between a N pole (left) and a S pole (right), running from front to back. The induced current in the wire flows towards the front (towards you). Which way is the wire being moved?
Use Fleming's RIGHT-hand rule for generators: First finger = Field (N โ S), seCond finger = induced Current, thuMb = Motion. Lining up field and current gives the motion: C.
BPart B 9 questions
Questions 11โ19.
A wire, connected in a circuit with an ammeter, sits between the N and S poles of a magnet. The wire is moved downwards (towards the bottom of the page), and a current is induced in it. Which way is the force on the wire due to this current?
The induced current always opposes the change that causes it. The wire is pushed down, so the force on it from the induced current acts upwards, opposing the motion.
A simple a.c. generator has a coil turning between N and S poles, connected through slip rings to points X and Y. The graph of the p.d. between X and Y against time is a sine curve that starts at zero and rises first (positive means X is more positive than Y). Point P is the first negative peak. Four diagrams show the coil. A: face-on, in the position it has at the positive peak. B: edge-on, a quarter of a turn on from A. C: face-on, half a turn on from A (its connections to the slip rings are the other way round). D: edge-on, three-quarters of a turn on from A. Which diagram shows the coil at P?
The p.d. is largest (positive or negative) when the sides of the coil cut the field lines fastest, and zero when the coil is edge-on to the poles (B and D) and its sides move along the field lines.
P is the negative peak, half a turn after the positive peak (A). After half a turn the coil is face-on again, but each side is now at the opposite pole, so the p.d. is reversed: that is C.
Pushing the S pole of a magnet into end X of a coil XY makes a galvanometer deflect to the left. Which other movement also gives a deflection to the left? A: S pole pulled out of end X. B: N pole pulled away from end Y. C: N pole pushed into end X. D: S pole pulled away from end Y.
In the example the S pole approaching X induces an S pole at X (to repel it), so Y is an N pole. In D the S pole leaving Y is attracted back, so Y is an N pole and X an S pole: the same as the example, so the same current direction.
Which graph of an a.c. generatorโs voltage is correctly labelled? A: humps above the axis only, peaks at the tops and zeros between; B: closer humps above the axis, similarly labelled; C: a sine wave with the peaks labelled at the tops and the zeros labelled at the troughs; D: a sine wave with peaks labelled at both the tops and the troughs, and zeros where it crosses the axis.
An a.c. generator gives a sine wave that goes both positive and negative. The peaks are the maximum values in both directions (tops and bottoms), and the zeros are where the graph crosses the time axis. Only D labels these correctly.
A 100% efficient transformer has 2000 turns on the primary and 10 000 on the secondary. Which is correct (V voltage, I current; p primary, s secondary)?
- Turns ratio10 000 รท 2000 = 5, so Vs = 5Vp
- 100% efficientpower in = power out, so Is = Ip รท 5 = 0.2Ip
- Aif both went up 5 times, the power out would be 25 times the power in: impossible.
- C, Dit has more secondary turns, so it steps the voltage UP.
What does the iron core of a simple transformer do?
The alternating current in the primary makes a changing magnetic field; the soft-iron core carries this field through the secondary, inducing a voltage there. No current flows through the core.
A transformer has 550 turns on its input coil and 115 turns on its output coil. The input voltage is 22 000 V. What is the output voltage?
- StepVs = 22 000 ร 115 รท 550
- StepVs = 4600 V (fewer turns: step-down)
In a basic electric motor, X is the rectangular loop of wire turning between the N and S poles; Y is the pair of contacts pressing against the ring, connected to the battery; Z is the split ring fixed on the axle. Name X, Y and Z.
X is the coil, Y the carbon brushes that press on the rotating Z, the split-ring commutator.
A 100%-efficient transformer has 5500 turns on the primary and 500 on the secondary. The secondary output is 110 V a.c., connected to a heater that produces 132 W. What is the current in the primary coil?
- StepVp = Vs ร Np รท Ns = 110 ร 5500 รท 500 = 1210 V
- Step100% efficient, so input power = 132 W
- StepIp = 132 รท 1210 = 0.11 A
Your overall result
Check every section above to fill this in. Your best attempt is remembered on this device.