Chapter-wise practice · Cambridge IGCSE · Chapter 23 · Test 3 of 11

Chapter 23: Radioactivity · Practice Test 3

19 multiple-choice questions on radioactivity, following chapter 23 of the Cambridge IGCSE Physics Coursebook. Most are real past-paper questions (2021–2026, rewritten in K2’s words); the rest come from the textbooks’ practice sections. Core questions come first, then Extended.

✓ 100% free 19 questions 17 from past papers 10 Core · 9 Extended Full solutions
How it works Part A Part B Results

How this practice test works

The questions cover every section of chapter 23:

  • 23.1 Radioactivity all around us
  • 23.2 Radioactive decay
  • 23.3 Activity and half-life
  • 23.4 Using radioisotopes

Each question shows where it is from (session, paper and question number, or the book), the section it tests, and whether it is Core (Paper 1/3) or Extended (Paper 2/4). Choose an answer for each question, tap Check my answers to mark that part, then Show solutions to see the working. Your best score is saved on this device.

APart A 10 questions

Questions 1–10.

1
CorePast paper · May/June 2025 · Paper 12 · Q3523.1 Radioactivity all around usalso asked in 1 other paper

Which list contains only natural sources of background radiation?

✔ AnswerC   rocks and buildings, food and drink, radon gas

Natural: radon, rocks and buildings, food and drink, cosmic rays. Nuclear power stations are man-made; mobile phones give no ionising radiation.

2
CorePast paper · May/June 2023 · Paper 13 · Q3623.1 Radioactivity all around us

What is a major source of background radiation?

✔ AnswerA   cosmic rays

Background radiation is ionising radiation. Major sources include radon gas, rocks and buildings, food, and cosmic rays. Microwaves and visible light are not ionising, and nuclear power stations contribute very little.

3
CorePast paper · May/June 2025 · Paper 12 · Q3623.2 Radioactive decayalso asked in 1 other paper

Comparing alpha, beta and gamma emissions, which statement is correct?

✔ AnswerA   alpha is the most ionising

Alpha is the most ionising (and least penetrating). Gamma is the most penetrating and is an EM wave, not particles; beta is fast electrons, not EM.

4
CorePast paper · Oct/Nov 2023 · Paper 11 · Q3523.2 Radioactive decayalso asked in 1 other paper

α-particles, β-particles and γ-rays are given out by decaying nuclei. Which can be deflected by an electric field?

✔ AnswerB   α and β only

α-particles (positive) and β-particles (negative) are charged, so an electric field deflects them (in opposite directions). γ-rays are uncharged electromagnetic waves.

5
CorePast paper · May/June 2021 · Paper 12 · Q3923.2 Radioactive decay

An atom decays by emitting a β-particle. Which row is correct?

✔ AnswerA   nucleus; different element

A β-particle comes from the nucleus: a neutron changes into a proton. The proton number goes up by one, so it becomes a different element.

6
CorePast paper · Oct/Nov 2025 · Paper 11 · Q3423.3 Activity and half-life

A radioactive source is 20 mm from a detector. The count rate is 2000 counts/minute. With thin paper in between it is still 2000 counts/minute; with 5 mm of aluminium in between it is 1200 counts/minute.

Which emissions come from the source?

✔ AnswerC   beta and gamma only

Paper stops alpha: no change, so no alpha. A few mm of aluminium stops beta: the drop to 1200 means there was beta. Counts still get through: gamma.

sourcepaper5 mm Alα?no α (no drop)β stoppedγ passes2000 → 2000 with paper:NO alpha2000 → 1200 with aluminium:some BETA was stoppedstill 1200 left: GAMMAbeta and gamma only (C)
Q34 Paper changes nothing, so there is no alpha. A few mm of aluminium removes some counts (beta) but leaves 1200 counts/min, which must be gamma.
7
CorePast paper · May/June 2023 · Paper 11 · Q3723.3 Activity and half-life

The count rate from a radioactive sample is measured for 80 minutes (time / min, count rate / counts per second): 0, 480; 20, 380; 40, 300; 60, 240; 80, 190. What is the half-life of the isotope?

✔ AnswerC   60 minutes
  1. Stephalf of 480 is 240 counts per second
  2. Step240 is reached at 60 minutes
  3. Check380 at 20 min halves to 190 at 80 min, again 60 minutes
From the examiner reportFew were correct; many chose B (40 minutes).
0 20 40 60 80 0 100 200 300 400 500 time / minutes count rate / counts per second 240 at 60 min half of 480 = 240reached at 60 mincheck: 380 → 19020 → 80 min= 60 min againhalf-life = 60 min
Q37 The half-life is the time for the count rate to fall to half: from 480 to 240 counts per second. That takes 60 minutes. (Check: from 380 at 20 min, half is 190 at 80 min, also 60 minutes later.)
8
CorePast paper · Oct/Nov 2022 · Paper 12 · Q3923.3 Activity and half-lifealso asked in 1 other paper

In an evacuated apparatus, absorbers can be placed between a radioactive source and a detector. Count rates: no absorber – 350 counts/s; thin paper – 350; 1.0 mm aluminium – 180; 1.0 cm lead – 23. Which radiations does the source emit?

✔ AnswerC   β and γ
  1. Steppaper changes nothing (350 → 350): no α
  2. Step1 mm aluminium cuts the count to 180: some β was stopped
  3. Stepradiation still gets through 1 mm of aluminium, and some even through 1 cm of lead (23 counts/s): only γ can do that
9
CoreBook practice · Cambridge IGCSE Physics Coursebook (exam-style), Ch 2323.3 Activity and half-life

A source contains 240 g of a radioactive isotope with a half-life of 3.0 hours. How much of the isotope is left after 12 hours?

✔ AnswerC   15 g
  1. Step12 ÷ 3.0 = 4 half-lives
  2. Step240 → 120 → 60 → 30 → 15 g
Common mistakeThinking it is all gone after a few half-lives. The amount halves each time; it never reaches zero.
10
CoreBook practice · Marshall Cavendish IGCSE Physics (Let’s Review), Ch 2023.4 Using radioisotopes

A radioactive substance emits β-particles and γ-rays. What should its storage container be made of?

✔ AnswerA   lead

Aluminium would stop the β-particles, but only thick lead (or concrete) greatly reduces γ-rays.

BPart B 9 questions

Questions 11–19.

11
ExtendedPast paper · May/June 2026 · Paper 21 · Q3723.2 Radioactive decay

Radon decays to polonium: 22286Rn → 21884Po + X. What is X?

✔ AnswerA   an α-particle
  1. Nucleon number222 − 218 = 4
  2. Proton number86 − 84 = 2

X has A = 4, Z = 2: a helium nucleus, ⁴₂He, an α-particle.

12
ExtendedPast paper · Oct/Nov 2025 · Paper 21 · Q3423.2 Radioactive decay

Statements about α- and β-particles:

1  The size of the charge on an α-particle is twice that on a β-particle.

2  An α-particle is much more massive than a β-particle.

3  An α-particle has small kinetic energy compared with a β-particle.

Which help to explain why they ionise differently?

✔ AnswerB   1 and 2 only

The α-particle's larger charge (+2) pulls electrons off atoms more strongly, and its large mass makes it slow, so it spends longer near each atom. Statement 3 is false: α-particles usually have MORE kinetic energy than β-particles.

From the examiner reportAnswers were spread over all four options, suggesting guessing.
13
ExtendedPast paper · Oct/Nov 2024 · Paper 22 · Q3523.2 Radioactive decay

An α-particle and a β-particle have the same kinetic energy. Why does the α-particle ionise air more strongly?

✔ AnswerB   larger charge, smaller velocity: near each air particle for longer

α has twice the charge and, being much heavier, is much slower for the same energy, so it spends longer near each atom and pulls off electrons more easily.

14
ExtendedPast paper · Oct/Nov 2022 · Paper 21 · Q4023.2 Radioactive decay

What is the nature of α-emission?

✔ AnswerC   positively charged particles

An α-particle is a helium nucleus (2 protons + 2 neutrons), so it is a positively charged particle.

15
ExtendedPast paper · May/June 2026 · Paper 22 · Q3723.3 Activity and half-life

A radioactive isotope has a half-life of 8.0 days. Near a sample, a detector reads 200 counts per minute. With no source present, the background count is 20 counts per minute.

After 8.0 days, what is the count rate due to the source?

✔ AnswerB   90 counts per minute
  1. Source alone200 − 20 = 180 counts/min
  2. After one half-life180 ÷ 2 = 90 counts/min
  • A80: halves 200 and then subtracts 20.
  • C100: halves 200 and ignores the background.
  • D110 is what the detector would read (90 + 20), not the source alone.
From the examiner reportD was common: most subtracted the background at the start but then added it back on at the end.
200measuredat start20backgroundalways there180source only200 − 2090source onlyafter 8.0 days÷ 2Half-life is for theSOURCE count only180 → 90 counts/min(B)110 (D) = 90 + 20: that iswhat the detector wouldREAD, not the source alone
Q37 Subtract the background first: 200 − 20 = 180 counts/min from the source. One half-life (8.0 days) later the source gives half of that, 90 counts/min. The question asks for the count due to the source, so do not add the background back on.
16
ExtendedPast paper · May/June 2024 · Paper 21 · Q3623.3 Activity and half-life

A detector near a radioactive material reads 536 counts/s. The background count rate is 44 counts/s and the half-life is 34 hours. What will the detector read after 68 hours?

✔ AnswerD   167 counts/s
  1. Source only536 − 44 = 492
  2. 68 h = 2 half-lives492 → 246 → 123
  3. Stepreading = 123 + 44 = 167 counts/s
From the examiner reportB ignores the background; C forgets to add the background back at the end.
4920 h÷224634 h÷212368 hblue = source only; grey = background (44)source only: 536 − 44= 492 counts/s68 h = 2 half-lives492 → 246 → 123add background back:123 + 44 = 167
Q36 Remove the background first (536 − 44 = 492), halve twice for 68 hours (123), then add the background back: the detector reads 167 counts per second.
17
ExtendedPast paper · Oct/Nov 2024 · Paper 23 · Q3723.3 Activity and half-life

A β-source and detector on either side of paper control its thickness. The count rate falls as the paper gets thicker: it is 20 counts/s at 0.0 mm, 13 counts/s at 0.50 mm and 12 counts/s at 0.60 mm. The rollers squeeze the paper when the count rate falls below 12 counts/s and stop when it rises above 13 counts/s. How thick is the paper coming out?

✔ AnswerB   0.50 mm to 0.60 mm

Read across from 12 and 13 counts/s to the curve and down: the paper is kept between about 0.50 and 0.60 mm thick. Thicker paper absorbs more β, so the count rate falls.

18
ExtendedPast paper · Oct/Nov 2021 · Paper 21 · Q3823.3 Activity and half-life

A detector near a radioactive sample records these count rates (counts/min): 0 h – 530; 1 h – 438; 2 h – 363; 3 h – 301; 4 h – 251; 5 h – 210; 6 h – 177; 8 h – 128; 10 h – 95. The background count rate is 30 counts/min. What is the half-life of the sample?

✔ AnswerA   3.4 h
  1. From the sample530 − 30 = 500 counts/min
  2. Half250; detector reading 250 + 30 = 280
  3. Stepreading falls to 280 at about 3.4 h
From the examiner reportMost subtracted the background and halved (250) but forgot to add the background back before reading the graph.
0 2 4 6 8 10 0 100 200 300 400 500 600 time / h count rate / counts per min background 30 250 + 30 = 280 530 − 30 = 500from the samplehalf: 250+ background 30look for 280t½ ≈ 3.4 h
Q38 Take off the background first: 530 − 30 = 500 counts/min from the sample. Half of that is 250, but the detector also always reads the 30 background, so look for 250 + 30 = 280 counts/min on the graph. That is reached at about 3.4 h: the half-life.
19
ExtendedPast paper · May/June 2022 · Paper 22 · Q3923.4 Using radioisotopes

Which radioactive source is used in a smoke alarm, and why?

✔ AnswerB   α; most ionisation

An α source strongly ionises the air in the detector, giving a current. Smoke absorbs the α-particles, the current falls and the alarm sounds. α is also stopped by the casing.

Your overall result

Check every section above to fill this in. Your best attempt is remembered on this device.

Answer and check at least one section to see your score here.
100% free

Everything on K2 Physics is free

3D labs, notes for every chapter, IGCSE past paper solutions and quizzes. No sign-up, no payment, no access codes.

Want a teacher as well? Live classes start with a free demo class. Book a demo class →